Vendor: Dynamic Lamps

500PAR64WFL 500W 120V GX16D Clear Halogen WFL Lamp

Regular price 34.99 USD
Shipping calculated at checkout.
In stock

Buy with confidence

Need help confirming compatibility? Ask us before ordering.

Shipping calculated at checkout · 30-day returns on unused items

Confirm before ordering

Match the exact manufacturer or ANSI code, wattage, voltage or current rating, base, bulb/reflector form, dimensions, filament, and operating position shown below. Similar-looking halogen lamps are not automatically interchangeable.

Need help confirming fit? Email help@dynamiclamps.com with the equipment manufacturer, model, and existing lamp marking.

Specifications

500PAR64WFL 500W 120V GX16D Clear Halogen WFL Lamp specifications

Shopify SKU GEN-500PAR64WFL
Electrical rating 500 Watt 120 Volt
Base / connection GX16D EXT Extended Mogul End Prong Base
Rated average life 2000 Hours Rated Average Life
Light output 6500 Initial Lumens
Color temperature 2800K Color Temperature
Product detail 13000 Center Beam Candle Power
Product detail 55 Degree Horizontal Beam Spread
Product detail 20 Degree Vertical Beam Spread
Optical / finish Clear Lamp
Bulb / form PAR64 Shape
Product detail Wide Flood (WFL)
Product detail Sealed Beam-PAR
Filament CC-13 Filament
Maximum overall length 6.0 in (152.4 mm) Max Overall Length
Bulb / form 8.0 in (203.2 mm) Bulb Diameter
Other part numbers 39412, 500PAR64/WFL
Equipment compatibility

Equipment and application fit

Used in theatrical, stage, and studio lighting

  • Use only in equipment whose lamp list and electrical, optical, thermal, and mechanical design specify this exact lamp or a fully documented equivalent.

Socket fit alone does not establish compatibility. The equipment label, current service manual, and installed-lamp marking take precedence.

Brand alternatives

Cross-reference search aids

39412, 500PAR64/WFL

Confirm any substitute against the complete electrical, mechanical, optical, filament, dimensional, and operating specification. A shared ANSI code may identify a lamp family but does not override equipment requirements.

Documentation & safety

Manufacturer documentation and handling

No manufacturer data-sheet link is attached to this record. Confirm the current lamp marking and equipment documentation before installation.

Halogen safety: Disconnect power and allow the equipment to cool before service. Install only in approved enclosed equipment with the required protective screen, ventilation, electrical controls, and shielding. Handle quartz with clean gloves or lint-free tissue and avoid touching the envelope with bare skin.