{"title":"Mercury Short-Arc Replacement Lamps","description":"\u003cp\u003eCompare selected OSRAM HBO mercury short-arc replacement lamps for equipment that specifies these exact lamp types.\u003c\/p\u003e\u003cp\u003eThe HBO 200 W\/4 and HBO R 103 W\/45 are \u003cstrong\u003edifferent lamps, not interchangeable alternatives\u003c\/strong\u003e. Match the full part number, electrical rating, base or reflector, dimensions and equipment revision before ordering. Check each product page for exact specifications and supported compatibility.\u003c\/p\u003e\u003cp\u003eNeed help matching an existing lamp? \u003ca href=\"\/pages\/customer-support-help\"\u003eSend Dynamic Lamps the complete lamp marking and equipment model\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"69311-osram-hbo-r-103-w-45-dc-100w-25v-mercury-short-arc-lamp","title":"69311 OSRAM HBO R 103 W\/45 103W DC Mercury Short-Arc Reflector Lamp","description":"\u003csection class=\"dl-confirm-panel\"\u003e\n  \u003ch2\u003eConfirm before ordering\u003c\/h2\u003e\n  \u003cp\u003eMatch \u003cstrong\u003eOSRAM 69311\u003c\/strong\u003e, \u003cstrong\u003eHBO R 103 W\/45\u003c\/strong\u003e, the \u003cstrong\u003e45 mm reflector focal distance\u003c\/strong\u003e, and the equipment's \u003cstrong\u003e20–25 V DC\u003c\/strong\u003e lamp circuit. Double-ended HBO 100 W\/2 or HBO 103 W\/2 lamps and similarly sized reflector lamps are not automatic substitutes.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003cdetails class=\"dl-product-panel\" id=\"dl-osr-69311-specifications\" open\u003e\n  \u003csummary\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cdiv class=\"dl-product-panel__content\"\u003e\n    \u003ctable\u003e\u003ctbody\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eOSRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmericas product number\u003c\/th\u003e\n\u003ctd\u003e69311\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eLamp designation\u003c\/th\u003e\n\u003ctd\u003eHBO R 103 W\/45\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eGTIN \/ EAN\u003c\/th\u003e\n\u003ctd\u003e4050300405957\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eTechnology\u003c\/th\u003e\n\u003ctd\u003eMercury short-arc lamp with integrated reflector\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal power\u003c\/th\u003e\n\u003ctd\u003e103 W\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eLamp voltage\u003c\/th\u003e\n\u003ctd\u003e20–25 V\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eLamp current\u003c\/th\u003e\n\u003ctd\u003e4.0–5.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent type\u003c\/th\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eBase\u003c\/th\u003e\n\u003ctd\u003eFaXP2.5-2x65\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eReflector focal distance\u003c\/th\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal life\u003c\/th\u003e\n\u003ctd\u003e300 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eDiameter\u003c\/th\u003e\n\u003ctd\u003e68 mm (2.677 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eLength\u003c\/th\u003e\n\u003ctd\u003e85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e120 g\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating position\u003c\/th\u003e\n\u003ctd\u003ep20; follow the lamp marking and equipment instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eRequired\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\u003c\/table\u003e\n  \u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"dl-product-panel\" id=\"dl-osr-69311-compatibility\"\u003e\n  \u003csummary\u003e\u003cstrong\u003eEquipment compatibility\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cdiv class=\"dl-product-panel__content\"\u003e\n    \u003ch2\u003eDocumented equipment reference\u003c\/h2\u003e\n    \u003cp\u003eThe following system is listed for the complete 69311 \/ HBO R 103 W\/45 lamp identity. Confirm the equipment nameplate, DC supply, connector, 45 mm optical geometry, cooling, and lamp-holder configuration before installation.\u003c\/p\u003e\n    \u003cdiv class=\"dl-equipment-reference\"\u003e\u003cul class=\"dl-equipment-reference__list\" data-dl-equipment-list\u003e\u003cli\u003eDentsply \/ L.D. Caulk Fiber Optic System specified for OSRAM 69311 \/ HBO R 103 W\/45\u003c\/li\u003e\u003c\/ul\u003e\u003c\/div\u003e\n    \u003cp\u003e\u003csmall\u003eOSRAM also identifies this lamp family for microscopy, laboratory analysis, UV curing, fiber illumination, and solar simulation. Those are application classes, not guarantees of fit in every device.\u003c\/small\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"dl-product-panel\" id=\"dl-osr-69311-alternatives\"\u003e\n  \u003csummary\u003e\u003cstrong\u003eBrand alternatives and related lamps\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cdiv class=\"dl-product-panel__content\"\u003e\n    \u003ch2\u003eNo automatic substitute is linked\u003c\/h2\u003e\n    \u003cp\u003eThe integrated reflector, 45 mm focal distance, electrical range, pin arrangement, and cooling requirement are all part of this lamp's identity. Do not replace it with a double-ended HBO lamp or another reflector lamp unless the equipment manufacturer specifies the complete alternate designation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"dl-product-panel\" id=\"dl-osr-69311-documentation\"\u003e\n  \u003csummary\u003e\u003cstrong\u003eDocumentation and safety\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cdiv class=\"dl-product-panel__content\"\u003e\n    \u003cul\u003e\n      \u003cli\u003e\u003ca href=\"https:\/\/www.osram.com\/appsj\/pdc\/pdf.do?cid=GPS01_34047926\u0026amp;lid=EN\u0026amp;mpid=ZMP_56334\u0026amp;vid=MP_EUROPE_Europe_eCat\" rel=\"noopener\" target=\"_blank\"\u003eOSRAM HBO R 103 W\/45 product data sheet\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca href=\"https:\/\/look.ams-osram.com\/m\/5c68e2ced33f62a6\/original\/Medical-brochure-EN.pdf\" rel=\"noopener\" target=\"_blank\"\u003eOSRAM medical and scientific lamp brochure\u003c\/a\u003e\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\u003cstrong\u003eSafety:\u003c\/strong\u003e This pressurized mercury short-arc lamp emits intense ultraviolet radiation and requires a dedicated power supply and cooling. Operate it only in an enclosed housing designed for this lamp. Disconnect power, allow full cooling, wear the equipment manufacturer's protective gear, avoid touching optical surfaces, and follow applicable mercury-lamp handling and disposal requirements.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/details\u003e\n\u003csection class=\"lamp-matching-help\"\u003e\u003ch2\u003eNeed help matching this replacement lamp?\u003c\/h2\u003e\n\u003cp\u003eUse our \u003ca href=\"\/pages\/specialty-lighting\"\u003especialty lamp matching guide\u003c\/a\u003e, or \u003ca href=\"\/pages\/customer-support-help\"\u003esend the full lamp markings and equipment model for help\u003c\/a\u003e. For a quantity or repeat-order inquiry, include the exact part number, quantity, delivery postal code and requested timing.\u003c\/p\u003e\u003c\/section\u003e","brand":"Osram","offers":[{"title":"Default Title","offer_id":42207741280292,"sku":"OSR-69311","price":689.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0189\/1890\/files\/69311_Osram_Lamp.jpg?v=1743619439"},{"product_id":"69224-osram-hbo-200-w-4-200w-mercury-short-arc-lamp","title":"69224 OSRAM HBO 200 W\/4 200W Mercury Short Arc Lamp","description":"\u003csection class=\"dl-confirm-panel\"\u003e\n  \u003ch2\u003eConfirm before ordering\u003c\/h2\u003e\n  \u003cp\u003eMatch \u003cstrong\u003eOSRAM 69224\u003c\/strong\u003e, \u003cstrong\u003eHBO 200 W\/4\u003c\/strong\u003e, and the equipment's \u003cstrong\u003eAC\u003c\/strong\u003e lamp circuit. HBO 200 W\/2, HBO 202 W\/4, and HBO 200 W\/DC variants have different electrical or spectral characteristics and are not automatic substitutes.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003cdetails class=\"dl-product-panel\" id=\"dl-osr-69224-specifications\" open\u003e\n  \u003csummary\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cdiv class=\"dl-product-panel__content\"\u003e\n    \u003ctable\u003e\u003ctbody\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eOSRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmericas product number\u003c\/th\u003e\n\u003ctd\u003e69224\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eLamp designation\u003c\/th\u003e\n\u003ctd\u003eHBO 200 W\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eGTIN \/ EAN\u003c\/th\u003e\n\u003ctd\u003e4050300506715\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eTechnology\u003c\/th\u003e\n\u003ctd\u003eDouble-ended high-pressure mercury short-arc lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated power\u003c\/th\u003e\n\u003ctd\u003e200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eLamp voltage\u003c\/th\u003e\n\u003ctd\u003e54–63 V\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eLamp current\u003c\/th\u003e\n\u003ctd\u003e3.0–3.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent type\u003c\/th\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnode base\u003c\/th\u003e\n\u003ctd\u003eSFc10-4\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eCathode base\u003c\/th\u003e\n\u003ctd\u003eSFc10-4\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal luminous flux\u003c\/th\u003e\n\u003ctd\u003e9,500 lm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eAverage rated life\u003c\/th\u003e\n\u003ctd\u003e200 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum overall length\u003c\/th\u003e\n\u003ctd\u003e128 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference length\u003c\/th\u003e\n\u003ctd\u003e102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eLamp-center distance\u003c\/th\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eDiameter\u003c\/th\u003e\n\u003ctd\u003e17 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating position\u003c\/th\u003e\n\u003ctd\u003es20 \/ restricted; follow the equipment diagram and lamp marking\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eConvection\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\u003c\/table\u003e\n  \u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"dl-product-panel\" id=\"dl-osr-69224-compatibility\"\u003e\n  \u003csummary\u003e\u003cstrong\u003eEquipment compatibility\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cdiv class=\"dl-product-panel__content\"\u003e\n    \u003ch2\u003eDocumented HBO 200 W\/4 microscope systems\u003c\/h2\u003e\n    \u003cp\u003eThese references specify the HBO 200 W\/4 burner or a lamp housing and supply configured for it. Confirm the exact illuminator, AC supply, starter, connector, and operating position because the same microscope stand can be equipped with a different lamp system.\u003c\/p\u003e\n    \u003cdiv class=\"dl-equipment-reference\"\u003e\u003cul class=\"dl-equipment-reference__list\" data-dl-equipment-list\u003e\n\u003cli\u003eReichert Me F2 microscope with the Meraquarius II C twin-lamp unit and HBO 200 W\/4 supply\u003c\/li\u003e\n\u003cli\u003eReichert Polyvar microscope with Lamp Housing W for HBO 200 W\/4 AC operation\u003c\/li\u003e\n\u003cli\u003eReichert Polyvar-Met microscope with Lamp Housing W and burner number 86 00 16\u003c\/li\u003e\n\u003cli\u003eReichert Univar microscope configured for the HBO 200 W\/4 high-pressure mercury lamp\u003c\/li\u003e\n\u003cli\u003eCarl Zeiss Axiomat microscope with Microscope Illuminator 250 configured for HBO 200 W\/4\u003c\/li\u003e\n\u003cli\u003eOlympus Vanox A-FL vertical fluorescence illuminator configured for OSRAM HBO 200 W\/4\u003c\/li\u003e\n\u003cli\u003eOlympus Vanox A-RFL vertical fluorescence illuminator configured for OSRAM HBO 200 W\/4\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n    \u003cp\u003e\u003csmall\u003eFor Reichert systems, the documented AC configuration uses Lamp Housing W; Lamp Housing G is associated with different DC lamp configurations.\u003c\/small\u003e\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"dl-product-panel\" id=\"dl-osr-69224-alternatives\"\u003e\n  \u003csummary\u003e\u003cstrong\u003eBrand alternatives and related lamps\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cdiv class=\"dl-product-panel__content\"\u003e\n    \u003ch2\u003eNo automatic substitute is linked\u003c\/h2\u003e\n    \u003cp\u003eHBO 202 W\/4 is a related AC lamp with enhanced short-wavelength output, while HBO 200 W\/DC and HBO 200 W\/2 versions use different circuits or bases. Use another designation only when the equipment manufacturer documents it for the installed lamp housing and supply.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"dl-product-panel\" id=\"dl-osr-69224-documentation\"\u003e\n  \u003csummary\u003e\u003cstrong\u003eDocumentation and safety\u003c\/strong\u003e\u003c\/summary\u003e\n  \u003cdiv class=\"dl-product-panel__content\"\u003e\n    \u003cul\u003e\n      \u003cli\u003e\u003ca href=\"https:\/\/www.osram.de\/appsj\/pdc\/pdf.do?cid=GPS01_34047918\u0026amp;lid=DE\u0026amp;mpid=ZMP_56329\u0026amp;vid=MP_EUROPE_DE_eCat\" rel=\"noopener\" target=\"_blank\"\u003eOSRAM HBO 200 W\/4 product data sheet\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca href=\"https:\/\/look.ams-osram.com\/m\/5c68e2ced33f62a6\/original\/Medical-brochure-EN.pdf\" rel=\"noopener\" target=\"_blank\"\u003eOSRAM medical and scientific lamp brochure\u003c\/a\u003e\u003c\/li\u003e\n      \u003cli\u003e\u003ca href=\"https:\/\/www.photonicmicrodevices.com\/files\/Reichert_Jung_Instructions_Manual.pdf\" rel=\"noopener\" target=\"_blank\"\u003eReichert Polyvar \/ Polyvar-Met operating instructions\u003c\/a\u003e\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\u003cstrong\u003eSafety:\u003c\/strong\u003e This pressurized mercury short-arc lamp emits intense ultraviolet radiation, requires high-voltage ignition, and can rupture. Operate it only in the specified enclosed housing and supply. Disconnect power, allow full cooling, wear the manufacturer's protective equipment, observe the marked orientation, and follow applicable mercury-lamp disposal requirements.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/details\u003e\n\u003csection class=\"lamp-matching-help\"\u003e\u003ch2\u003eNeed help matching this replacement lamp?\u003c\/h2\u003e\n\u003cp\u003eUse our \u003ca href=\"\/pages\/specialty-lighting\"\u003especialty lamp matching guide\u003c\/a\u003e, or \u003ca href=\"\/pages\/customer-support-help\"\u003esend the full lamp markings and equipment model for help\u003c\/a\u003e. For a quantity or repeat-order inquiry, include the exact part number, quantity, delivery postal code and requested timing.\u003c\/p\u003e\u003c\/section\u003e","brand":"Osram","offers":[{"title":"Default Title","offer_id":51318426599460,"sku":"OSR-69224","price":734.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0189\/1890\/files\/osram-69224-hbo-200w4.jpg?v=1787946415"}],"url":"https:\/\/www.dynamiclamps.com\/collections\/mercury-short-arc-replacement-lamps.oembed","provider":"Dynamic Lamps","version":"1.0","type":"link"}