Confirm before ordering
Match ELC/10H, Philips order code 136580, and the complete 250 W / 24 V / GX5.3 / 1,000 hours configuration. Standard ELC and the ELC-3, ELC-5, ELC-7, and ELC-10 classes can look alike but differ in life, output, color, filament, and optical performance.
Specifications
Philips ELC/10H long-life projection lamp
-
Manufacturer order code: 136580
-
Additional identifier: 12NC 924913220540 / full code 871150043686330
-
Life class: ELC/10H
-
Power: 250 W
-
Voltage: 24 V
-
Current: Approximately 10.4 A
-
Base: GX5.3 two-pin
-
Bulb / reflector: Smooth R50 reflector; UV-open quartz
-
Filament: Compact precision filament
-
Rated optical output: Not published in the current individual product sheet
-
Color temperature: 3400 K in the Philips specialty-lamp range table
-
Color rendering index: 100
-
Average rated life: 1,000 hours
-
Maximum overall length: 44.5 mm (1.75 in)
-
Diameter: 50 mm (1.97 in)
-
Working distance / focal reference: Confirm against the equipment optical specification
-
Product weight: 24 g
-
Operating position: Universal
Equipment compatibility
Qualified ELC-10 equipment classes
Reliable public model-level references were not found for this 1,000-hour class, so compatibility is intentionally limited to equipment that explicitly names ELC-10 or ELC/10H.
- Professional overhead-projection equipment explicitly specifying ELC-10 or ELC/10H
- Professional fiber-optic illuminators explicitly specifying ELC-10 or ELC/10H
- Entertainment fixtures explicitly specifying ELC-10 or ELC/10H
- One-hour photo-finishing equipment explicitly specifying ELC-10 or ELC/10H
The equipment manual and installed-lamp label take precedence.
Brand alternatives
Other ELC-10 choices
The linked products are in the same 1,000-hour ELC life class. Manufacturer optical specifications are not identical, so compare the full specification before substitution.
Documentation & safety
Manufacturer documentation
Philips ELC/10H product data
Safety
Use only in an approved enclosed professional fixture rated for 24V, 250W operation with the specified ELC life class, optical alignment, guards, ventilation, and cooling. Disconnect power and allow the fixture to cool completely before service. Handle the lamp and reflector with clean gloves or a lint-free cloth.