Metal-Halide Replacement Lamp Selector
Start with the full code on your old lamp or in your fixture’s parts list. A 50 W, 100 W or 150 W marking narrows the search, but it doesn’t identify the ballast, base or required enclosure.
Know the lamp code?
How to match a metal-halide lamp
- Copy the full lamp marking. Write down the maker, part number, all suffixes and rated wattage. Keep codes like /O, /830 and /942 intact. If the old lamp is unreadable, check the exact fixture model and revision in the parts list.
- Match the ballast and starting system. Check the ballast label against the lamp documentation for the applicable ANSI code and starting method. Compare lamp voltage and current where the maker specifies them; lamp operating voltage is not the fixture supply voltage.
- Check the base, bulb and clearances separately. Match the exact socket geometry and base key. Codes such as E26, EX39, G12 and G8.5 identify bases; ED17, BT37 and BT56 describe bulb shapes. Compare overall length, diameter and any optical dimensions called out by your fixture.
- Confirm enclosure and operating position. Match the lamp’s documented fixture requirement and permitted position to your equipment. Universal position does not make an enclosed-only lamp suitable for an open fixture. Type O does not waive other fixture requirements; Type S can have additional restrictions.
- Confirm the exact product and quantity. Use the product documentation to verify the full part number and what is included in the selling unit. If a required marking does not match, stop and identify the specified lamp before ordering.
If you only know the wattage, find the lamp and ballast labels before choosing. For a 150 W lamp in particular, identify whether it is a maintenance lamp, a compact ceramic lamp or a specialty equipment lamp. There is no single replacement for those uses.
Compare exact lamp markings
These are identification references, including some unavailable lamps. Open the exact product page to check current availability. A reference entry is not a promise of stock or equipment compatibility.
Match the maker and complete code before opening a product. These entries are options to compare, not interchangeable lamps. For stage, reflector and process equipment, match the exact marked lamp to your equipment documentation.
50 W maintenance
| Exact lamp | Maker watts | Base or connector | Ballast and fixture checks |
|---|---|---|---|
| GE 10361 · MXR50/U/MED | 50 W | E26 | ANSI M110 · enclosed rated |
100 W maintenance
| Exact lamp | Maker watts | Base or connector | Ballast and fixture checks |
|---|---|---|---|
| GE 12381 · MXR100/U/MED/O | 100 W | E26 | ANSI M90 · open rated in an appropriately rated luminaire · ED17 |
| GE 12652 · MVR100/U/MED | 100 W | E26 | ANSI M90 · enclosed rated · BD17 |
Other maintenance and compact ceramic
| Exact lamp | Maker watts | Base or connector | Ballast and fixture checks |
|---|---|---|---|
| GE 92585 · CMH70TCU830G8.5 | 70 W | G8.5 | ANSI C139/M139 · confirm the exact enclosure and control-gear requirements |
| OSRAM SYLVANIA 64032 · M250/U/ED28 | 250 W | E39 mogul | ANSI M58E · Enclosed (E) · ED28 clear, 211 mm |
| OSRAM SYLVANIA 64404 · MP250/BU-ONLY | 250 W | EX39 exclusionary mogul | ANSI M58/O · Type O (open-rated, in appropriate luminaire) · Base up within 15° only · BT28 clear |
| OSRAM SYLVANIA 64469 · M1000/U/BT37 | 1,000 W | E39 mogul | ANSI M47/E · Type E, enclosed · BT37 clear |
| OSRAM SYLVANIA 64468 · M1000/U | 1,000 W | E39 mogul | ANSI M47/S · Type S; check the manufacturer’s open-use restrictions · BT56 clear |
| Philips/Signify 223370 · CDM70/T6/830 | 70 W | G12 | ANSI C139/E · Enclosed only |
| Philips/Signify 91141100 · MASTERColour CDM-T Elite 70W/930 | 70 W designation | G12 | Totally enclosed even when testing · Match the Elite /930 marking and regional order code. |
Stage, reflector and other equipment lamps
| Exact lamp | Maker watts | Base or connector | Ballast and fixture checks |
|---|---|---|---|
| OSRAM SYLVANIA 54319 · SHARXS HTI 1500W/D7/60 | 1,500 W | SFc10-4 | Match the exact equipment specification, not wattage alone. |
| Philips/Signify 365791 · CDM-SA/R 150W/942 UNP/1 | 150 W designation | Ceramic Cap-Cable (C) | Match the cable and exact /R order code; not a G12 lamp. |
| Ushio 5001377 · MHR-250N | 250 W | AMP Connector | ANSI M80/E · E as published |
Equipment-specific EmArc lamps
EmArc is a separate DC discharge family. Match its exact lamp and equipment controller; a shared wattage does not make it a substitute for an AC metal-halide lamp.
| Exact lamp | Maker watts | Base or connector | Control-gear check |
|---|---|---|---|
| Ushio 5001466 · SMR-202/D1 | 160–200 W range | Confirm the connector on the original lamp | Dedicated equipment-specified EmArc DC driver/controller; match the exact SMR-202/D1 configuration. |
Industrial process lamps
These are equipment-specific process lamps. Confirm the exact process-lamp code, shielding and control gear in the equipment documentation.
| Exact lamp | Maker watts | Base or connector | Ballast and fixture checks |
|---|---|---|---|
| Ushio 5000061 · MHL-1000 | 1,000 W | Ceramic; AMP Connector contact | Match the full process-lamp suffix and equipment specification. |
| Ushio 5000065 · MHL-1007 | 1,000 W | Ceramic; AMP Connector contact | Match the full process-lamp suffix and equipment specification. |
| Ushio 5000071 · MHL-121HT | 3,000 W | Metal 14.3 mm; Metal contact | Match the full process-lamp suffix and equipment specification. |
| Ushio 5000082 · MHL-170L | 5,000 W | Ceramic; Spade Tongue contact | Match the full process-lamp suffix and equipment specification. |
| Ushio 5000090 · MHL-261L | 5,000 W | Ceramic; Spade Tongue contact | Match the full process-lamp suffix and equipment specification. |
| Ushio 5000106 · MHL-33LY | 6,000 W | Ceramic; AMP Connector contact | Match the full process-lamp suffix and equipment specification. |
| Ushio 5000107 · MHL-38KT | 6,000 W | Metal 12.7 mm; Metal contact | Match the full process-lamp suffix and equipment specification. |
| Ushio 5000114 · MHL-450 | 450 W | RSC; R7s contact | Match the full process-lamp suffix and equipment specification. |
| Ushio 5000118 · MHL-5000/4 | 5,000 W | Metal 14.3 mm; Metal contact | Match the full process-lamp suffix and equipment specification. · Separate /4 and /7 process variants. |
| Ushio 5000120 · MHL-5000/7 | 5,000 W | Metal 14.3 mm; Metal contact | Match the full process-lamp suffix and equipment specification. · Separate /4 and /7 process variants. |
| Ushio 5000127 · MHL-5020S | 5,000 W | Ceramic/THS; AMP Connector contact | Match the full process-lamp suffix and equipment specification. |
Common questions
Can I switch between lamps with the same wattage and base?
Check the full lamp, ballast and fixture markings first. For example, the 100 W GE lamps above share an M90 code but differ in lamp designation and enclosure requirements.
Can I use a metal-halide listing to pick an LED or high-pressure sodium replacement?
This guide covers metal-halide lamps only. Use your equipment manufacturer’s documentation for a technology change.
Can I identify a specialty lamp from its reflector or color?
Use the complete manufacturer order code and equipment instructions. Reflector shape, color or wattage alone does not determine the correct lamp.
Browse the metal-halide collection when you have the markings you need to compare.
Need help with a replacement or quantity order?
Send clear photos of the full lamp marking and ballast label, the fixture or equipment model and revision, quantity, delivery postal code and needed-by date.
Ask for exact-part identification help · Request a quantity or mixed-part quote
Manufacturer reference documents
These dated manufacturer references describe specific lamp configurations. Check the exact product documentation and equipment requirements; an older catalog does not establish the supplied lot or current availability.